Rabu, 12 Januari 2022

081362449440 Jual Flash and Fire Points by Cleveland Open Cup Method Jual Petroleum Oil & Gas Jakarta Indonesia measurement & testing equipment Contents ASTM D92, D93, D56 Viscosity ASTM D445, D446, D2170, 5293, D1200, D1200,D2983, D5481, D4684, D3829, D562, D4603, SAEJ300 Distillation ASTM D86, D1160, SH/T0165 Vapor Pressure ASTM D323 Cold behaviors ASTM D2386,D1177,D97,D2500,D6371 Oxidation stability ASTMD525,D2274,D4742,D943,D2112,D2272 Sulfur ASTMD3227,D1266,D1551,D4294,D5453 Corrosion ASTM D130, D4048, IP227 Existent gum ASTM D381, Q/SY LH00 Water content, water reaction ASTM D95, D4006, D4377, D4928, D6304, D1043, E203 Carbon Residue ASTM D524, D189, D4530 Mechanical impurities ASTM D4807 Acid value and acidity ASTM D3242, D664, D2896 Density ASTM D1298 FIA ASTM D1319 Color ASTM D1500, D156 Calorimeter ASTM D240 Ash content ASTM D482, D874 Sediment ASTM D473, D1290, D1796, D2709, D4007, D91, D96 Solid Particulate ASTM D2276 Penetration ASTM D217,D5,D1321,D937,D1403, D2884 and D4950, IP49,50 ,179,310,DIN51579, 51580, 51804, FTM791-311,791-312,791-313, AOCS Cc16-60, AACC58-14, NFT60-119, 60-123, 60-132,66-004 Evaporation loss ASTM D5800, D972 Brake fluid and engine coolants ASTM D1120, D1384, D4340, D2240 LPG test ASTM D1657, D2158,D1837, D1267, D1838, D2420 72~74 Transformer oil ASTM D1816, D924 Softening point HK-4507 Series Softening Point of Asphalt (Ring-and-Ball Test apparatus) ASTM D36, ASTM D2398 Tribology ASTMD2783,D2266,D4172,D2509,D2782,D6079 Rust-Preventing Characteristics HK-11143 . Rust-Preventing Characteristics of Inhibited Mineral Oil ASTM D665 Shear Stability HK-6278 Shear Stability of Polymer Containing Fluids ASTM D6278 Anti foaming Demulsibility ASTM D892, D6082 HK-7305 Water Separability for Lubricating Oils ASTM D1401 HK-8022 Apparatus for Demulsibility Characteristics of Lubricating Oils ASTM D8022 Air Release HK-0308 Air Release Value Apparatus ASTM D3427 Oil separation HK-0324 Oil Separation Apparatus (Conical Sieve Method) ASTM D6184 HK-392 Grease Separation Apparatus GB/T392 1742 Grease Separation Apparatus Roll stability ASTM D1742 HK-0122 Roll Stability for Lubricating Grease ASTM D1831 Water Washout HK-0109 Water Washout Characteristics Of Lubricating Grease ASTM D1264 Dropping Point ASTM D566, D2265 Flash Point HK-3536 Manual Cleveland Open Cup Apparatus ASTM D92 HK-3536A Semi Automatic Cleveland Open Cup Apparatus ASTM D92 HK-3536B Automatic Cleveland Open Cup Apparatus ASTM D92 HK-261 Manual Pensky-Martens Closed-cup Flash Point Apparatus ASTM D93 HK-261A Semi Automatic Pensky-Martens Closed-cup Flash Point Apparatus ASTM D93 HK-261B Automatic Pensky-Martens Closed-cup Flash Point Apparatus ASTM D93 HK-21929A Automatic Tag Closed Cup Flash Point Apparatus ASTM D56 HK-21789 Abel Closed Cup Flash Point Tester ASTM D56



BINTANG INSTRUMENT
HP : 081362449440 , 081310157965
Email : b081362449440@yahoo.com
Up. Mr Jonathan
=======================================================
Semi Automatic Cleveland Open Cup Flash Point Apparatus Manufacturers, Semi Automatic Cleveland Open Cup Flash Point Apparatus Factory, Supply Semi Automatic Cleveland Open Cup Flash Point Apparatus


Description: C:\Users\Jonathan\AppData\Local\Temp\msohtmlclip1\01\clip_image003.gif


    Flash and Fire Points by Cleveland Open Cup Method
BI-3536 Manual Cleveland Open Cup Apparatus conforms to the ASTM D92 Test Standard
Method for Flash and Fire Points by Cleveland Open Cup Tester. It uses Cleveland Open- Cup Method to test the flash point & fire point of lubricating oil and fuscous petroleum products (excluding fuel oil and petroleum products with open flash point lower than 79°C ).

Model: BI-3536
Features
        Quartz tube heating
Technical Parameters

Rated Voltage
AC220V±10% 50Hz

Power

0~1000W, Continuous adjustable
Measuring Range
90~400
Ignition Gas
Pipe gas or LPG, Pressure10kPa
Ignition Method
Manual
Ambient requirement
Temperature: 5~40, Humidity85%


Model: BI-3536A Semi Automatic
Features
        Quartz tube heating, glow plug
        Multifunction remote control box, remote ignition
        Full stainless steel gas pipeline
        High precision micro needle valve
        Stainless steel ceramic igniter
Technical Parameters

Rated Voltage
AC220V±10% 50Hz
Power
0~1000W, Continuous adjustable
Measuring Range
90~400
Ignition Gas
Pipe gas or LPG, Pressure10kPa
Ignition Method
Remote Ignition

Model: BI-3536B Automatic
Features
        Quartz tube heating, glow plug
        Independent heating module with detecting interface, heating
according to the standard requirement
        Automatic ignition, detection, alarm, save the result and air cooling
        Standard reagent calibration
Technical Parameters




    Flash Point by Pensky-Martens Closed Cup Method

BI-261 Manual Pensky-Martens Closed-cup Flash Point Apparatus conforms to the ASTM D93

Standard Test Methods for Flash Point by Pensky-Martens Closed Cup Tester. It is used to test for those liquids which have a kinematic viscosity of 5.8 mm 2/s (cSt) or more at 37.8°C or 9.5 mm 2/s (cSt) or more at 25°C (77°F), or that contain suspended solids, or have a tendency to form a surface film while under test. Other classification flash points have been established by these departments for liquids using these test methods.
Model: BI-261

Features

        Imported silicone tube

        Speed conversion switch

Technical Parameters

Rated Voltage                      AC220V±10% 50Hz
Power                                    0~1000W, Continuous adjustable
Measuring Range                40~300
Stirring mode                       Motor stir, 90~120rpm, 250±10rpm Ignition Gas                          Pipe gas or LPG, Pressure10kPa Ignition Method                  Manual
Ambient requirement        Temperature: 5~40, Humidity85%




Model: BI-261A Semi Automatic

Features

        Remote control operation

        Full stainless steel gas pipeline

        High precision micro needle valve

Technical Parameters


Rated Voltage                      AC220V±10% 50Hz
Power                                    0~1000W, Continuous adjustable
Measuring Range                40~300
Stirring mode                       Motor stir, 90~120rpm, 250±10rpm Ignition Gas                          Pipe gas or LPG, Pressure10kPa Ignition Method                  Remote control
Ambient requirement        Temperature: 5~40, Humidity85%





Model: BI-261B Automatic

Features

        Touch screen control, can connect to PC

                 Independent heating module with detecting interface, heating according to the standard requirement.
        Automatic ignition, detection, alarm, save the result and air cooling

        Standard reagent calibration

        Conforms to the ASTM D93,procedure A,B and C

Technical Parameters

Rated Voltage
AC220V±10% 50Hz
Power
700W
Sensor
Imported Glass Pt100
Ignition Method
Automatic
Repetitive error
±1





    Flash Point by Tag Closed Cup Method
BI-21929A Automatic Tag closed cup flash point apparatus conforms to the ASTM D56 Standard Test Method for Flash Point by Tag Closed Cup Tester, it is used For flash point determinations of liquids with a viscosity of below 5.5 centistokes (cSt) at 104°F (40°C) or below 9.5cSt at 77°F (25°C), and a flash point below 200°F (93°C) except cut-back asphalts
Model: BI-21929 Automatic Tag Closed Cup flash point
Features
        Fast refrigerating speed, big depth, could do -50 oil sample test.
        Ion ring detects flash point automatically, on/off scribing ignition automatically.
        From room temperature to -60 just needs 30min.
        Realize slope temperature rising, 3/min, 1/min.
        Equips with liquid level overflow port and liquid adding port.
        Glass PT100, temperature sensing rate is same as thermometer.
        Touch screen operation, thermal printer, store thousands of data.
        Equips unknown flash point detection
Technical Parameters

Rated Voltage
AC220V±10% 50Hz
Power
1500W
Test temperature
-40~70
Ignition Gas
Pipe gas or LPG, Pressure10kPa
Cooling mode
Imported compound compressor
Unknown flash point
function

equipped
Ambient requirement
Temperature: 5~40, Humidity85%





    Abel Closed Cup Flash Point Tester
BI-21789 Abel Closed Cup Flash Point Tester conforms to ISO13736 Petroleum Products and Other Liquids - Determination of Flash Point- Abel Closed Cup Method. It is used For flash point determinations of liquids with a viscosity of below 5.5 centistokes (cSt) at 104°F (40°C) or below 9.5cSt at 77°F (25°C), and a flash point below 200°F (93°C) except cut-back asphalts, those liquids which tend to form a surface film under test conditions and materials which contain suspended solids. We use gas supply for the apparatus, gas circuit adopts stainless steel pipe, anti-aging, constant using. The instrument is highly automated with simple operation and accurate result. The instrument is equipped with two Danfoss compressors as cooling system, test lowest flash point temperature can reach minus
50 degree.
This model can be used to measure the flash point of jet fuel

    Model: BI-21789 Abel Closed Cup Flash Point Tester
Features
        Fast refrigerating speed, big depth, could do -50 oil sample test.
        Ion ring detects flash point automatically, on/off scribing ignition automatically.
        From room temperature to -60 just needs 30min.
        Realize slope temperature rising, 3/min, 1/min.
        Equips with liquid level overflow port and liquid adding port.
        Glass PT100, temperature sensing rate is same as thermometer.
        Touch screen operation, thermal printer, store thousands of data.
        Equips unknown flash point detection
Technical Parameters
Rated Voltage                      AC220V±10% 50Hz
Power                                    350W Ignition                                  Gas
Measuring range                 -30~70
Stirring speed                      30r/min
Repetitive error                   <±1
Ambient requirement        5~40, Humidity85%


 