BINTANG INSTRUMENT
HP : 081362449440 , 081310157965
Email : b081362449440@yahoo.com
Up. Mr Jonathan
=======================================================
HP : 081362449440 , 081310157965
Email : b081362449440@yahoo.com
Up. Mr Jonathan
=======================================================
Flash and Fire Points by Cleveland Open Cup
Method
BI-3536 Manual Cleveland Open Cup Apparatus conforms to the ASTM D92 Test Standard
Method for Flash and Fire Points by Cleveland Open Cup Tester. It uses Cleveland Open- Cup Method
to
test the flash point & fire point of lubricating oil and
fuscous petroleum products (excluding fuel oil and petroleum products with open flash point lower than 79°C ).
Model: BI-3536
Features
Quartz tube heating
Technical Parameters
Rated
Voltage
|
AC220V±10% 50Hz
|
Power
|
0~1000W, Continuous adjustable
|
Measuring Range
|
90~400℃
|
Ignition Gas
|
Pipe gas or LPG, Pressure≤10kPa
|
Ignition Method
|
Manual
|
Ambient requirement
|
Temperature: 5~40℃, Humidity≤85%
|
Model: BI-3536A Semi
Automatic
Features
Quartz tube heating, glow plug
Multifunction remote control box, remote ignition
Full stainless steel gas pipeline
High precision micro needle valve
Stainless steel ceramic igniter
Technical Parameters
Rated
Voltage
|
AC220V±10% 50Hz
|
Power
|
0~1000W, Continuous adjustable
|
Measuring Range
|
90~400℃
|
Ignition Gas
|
Pipe gas or LPG, Pressure≤10kPa
|
Ignition Method
|
Remote Ignition
|
Model: BI-3536B Automatic
Features
Quartz tube heating, glow plug
Independent heating module with detecting
interface, heating
according
to
the standard requirement
Automatic ignition, detection, alarm, save the result and
air cooling
Standard reagent calibration
Technical Parameters
Flash Point by
Pensky-Martens Closed Cup Method
BI-261 Manual Pensky-Martens Closed-cup Flash Point Apparatus conforms to the ASTM
D93
Standard Test Methods for Flash Point by Pensky-Martens
Closed Cup Tester. It is used
to
test for those liquids which have a kinematic viscosity
of 5.8 mm 2/s (cSt) or more at 37.8°C or 9.5 mm 2/s (cSt) or more at 25°C
(77°F), or that contain suspended solids, or have a tendency to form a surface film while under test. Other classification flash points have been established
by these departments for
liquids using these test
methods.
Model: BI-261
Features
Imported silicone tube
Speed conversion switch
Technical Parameters
Rated Voltage AC220V±10% 50Hz
Power 0~1000W, Continuous adjustable
Measuring Range 40~300℃
Stirring mode Motor stir, 90~120rpm, 250±10rpm
Ignition Gas
Pipe gas or LPG, Pressure≤10kPa Ignition Method Manual
Ambient requirement
Temperature: 5~40℃, Humidity≤85%
Model: BI-261A Semi Automatic
Features
Remote control operation
Full stainless steel gas pipeline
High precision micro needle valve
Technical Parameters
Rated Voltage AC220V±10% 50Hz
Power 0~1000W, Continuous adjustable
Measuring Range 40~300℃
Stirring mode Motor stir, 90~120rpm, 250±10rpm
Ignition Gas
Pipe gas or LPG, Pressure≤10kPa Ignition Method Remote control
Ambient requirement
Temperature: 5~40℃, Humidity≤85%
Model: BI-261B Automatic
Features
Touch screen control, can connect to PC
Independent heating module with
detecting interface, heating
according to the standard
requirement.
Automatic ignition, detection, alarm, save the result and air cooling
Standard reagent calibration
Conforms to the ASTM
D93,procedure A,B and
C
Technical Parameters
Rated
Voltage
|
AC220V±10% 50Hz
|
Power
|
700W
|
Sensor
|
Imported
Glass Pt100
|
Ignition Method
|
Automatic
|
Repetitive error
|
±1℃
|
Flash Point by
Tag
Closed Cup Method
BI-21929A Automatic Tag closed cup flash
point apparatus conforms to the ASTM
D56
Standard Test Method for
Flash Point by Tag Closed Cup Tester, it is used For flash point determinations of liquids with a viscosity of below 5.5 centistokes (cSt) at 104°F (40°C) or below 9.5cSt at 77°F (25°C), and a flash
point below
200°F (93°C)
except cut-back asphalts
Model: BI-21929 Automatic Tag
Closed Cup flash point
Features
Fast refrigerating
speed, big
depth, could
do
-50℃ oil sample test.
Ion ring detects flash point automatically, on/off
scribing ignition automatically.
From room temperature to -60℃ just needs 30min.
Realize slope temperature rising, 3℃/min, 1℃/min.
Equips with liquid
level overflow port and
liquid adding port.
Glass PT100, temperature sensing
rate is same as thermometer.
Touch screen operation, thermal printer, store thousands of
data.
Equips unknown
flash point detection
Technical Parameters
Rated
Voltage
|
AC220V±10% 50Hz
|
Power
|
1500W
|
Test temperature
|
-40~70℃
|
Ignition Gas
|
Pipe gas or LPG, Pressure≤10kPa
|
Cooling mode
|
Imported
compound
compressor
|
Unknown
flash point
function
|
equipped
|
Ambient requirement
|
Temperature: 5~40℃, Humidity≤85%
|
Abel Closed Cup Flash Point Tester
BI-21789 Abel Closed Cup Flash Point Tester conforms to ISO13736 Petroleum Products and Other
Liquids - Determination of Flash Point-
Abel Closed Cup Method. It is used For flash point determinations of liquids with a viscosity of
below 5.5 centistokes (cSt)
at 104°F (40°C) or below 9.5cSt at 77°F (25°C), and a flash point below
200°F (93°C) except cut-back asphalts, those liquids which tend to form a surface film under test
conditions and materials which contain suspended solids.
We use gas
supply for the apparatus, gas circuit adopts stainless steel pipe, anti-aging, constant
using.
The
instrument is highly automated with simple operation
and
accurate result. The instrument
is equipped with two Danfoss compressors as cooling system, test lowest
flash
point
temperature can
reach
minus
50 degree.
This model can be used to measure the flash point
of jet fuel
Model: BI-21789 Abel
Closed Cup Flash Point Tester
Features
Fast refrigerating
speed, big depth, could do -50℃ oil sample test.
Ion ring detects flash point automatically, on/off
scribing ignition automatically.
From room temperature to -60℃ just needs 30min.
Realize slope temperature rising, 3℃/min, 1℃/min.
Equips with liquid
level overflow port and
liquid adding port.
Glass PT100, temperature sensing
rate is same as thermometer.
Touch screen operation, thermal printer, store thousands of
data.
Equips unknown
flash point detection
Technical Parameters
Rated Voltage AC220V±10% 50Hz
Power 350W Ignition Gas
Measuring range -30~70℃
Stirring speed 30r/min
Repetitive error <±1℃
Ambient requirement 5~40℃, Humidity≤85%