Jumat, 04 Agustus 2023

081362449440 Jual Online Water Quality Meter Online Water Quality Controller TSS Meter Controller TSS Meter Online TSS Meter Monitoring TSS Quality Meter Distributor TSS Meter Jakarta Indonesia Brochure TSS Meter

 BINTANG INSTRUMENT 

HP/WA   : 081362449440 / 081310157965 

Email      : b081362449440@yahoo.com 

Up           : Mr Jonathan 

=======================================================





pH/ORP Controller Model:APX1-C1A Power: AC100~240VAC 50~60Hz Main test object: pH or ORP Measuring principle: pH: Glass pH electrode (hydrogen ion concentration index) ORP: platinum or gold electrode (oxidation reduction potential) Measuring range/resolution: pH: 0~14pH / pH: 0.01pH ORP: ±2000mV / ORP: 1mV Temperature: -20~150℃ / Temperature: 0.1℃ Temperature compensation: Manual/automatic selection Accuracy: 0.1% of the measuring range (PH: ±0.02pH, ORP: ±2mV), whichever is greater Stability: 0.05% of measuring range per 24 hours, no accumulation Repeatability: better than 0.1% of the measuring range Display screen: 3.2-inch LCD display Instrument operation: PET button panel with 4 buttons Calibration method: pH: 3 points, double slope calibration, calibration points can be set freely; ORP: 2-point calibration On-site comparison for offset correction calibration Power-off protection: the instrument is powered off, and the set data is permanently retained Menu password:Six-digit password setting Relay output: Two settable SPST relays, maximum load 3A/250VAC Setup objects: including high/low alarms, water temperature or wash controls Protection level:IP66 Operating environment: 0~60℃ Storage environment: -20~70℃ Instrument dimensions: 100*100*120mm Installation size: 92*92mm Installation method: cabinet panel installation Shell Material: Reinforced ABS Electrical interface: 3 M12*1.5 Glen heads are reserved at the back end of the instrument, and the wire diameter is 3~6.5mm Maximum power: 3W max Temperature unit: NTC10K/PT1000 System language: English (support customization) Current output: One settable 0/4~20mA current loop outputs, max load 1000Ω, support long-term calibration Digital Communications: Without pH/ORP Controller Model:APX1-C1 D Power: DC:+18~36VDC pH/ORP Controller Model:APX1-C1Z-A Power: AC100~240VAC 50~60Hz Temperature unit: NTC10K/PT1000 System language: English (support customization) Relay output: Current output: One settable 0/4~20mA current loop outputs, max load 1000Ω, support long-term calibration Digital Communications: Two-wire RS485 interface, MODBUS RTU pH/ORP Controller Model:APX1-C1Z-D Power: DC:+18~36VDC pH/ORP Controller Model:APX1-C2-A Power: AC100~240VAC 50~60Hz Temperature unit: NTC10K/PT1000 System language:English (support customization) Current output: Two settable 0/4~20mA current loop outputs, max load 1000Ω, support long-term calibration Digital Communications: Two-wire RS485 interface, MODBUS RTU pH/ORP Controller Model:APX1-C2-D Power: DC:+18~36VDC pH/ORP Controller Model:APX1-G2-A Power: AC100~240VAC 50~60Hz Temperature unit: NTC10K/PT1000 Temperature compensation:Added 25°C conversion System language:English & China (support customization) Current output: Two settable 0/4~20mA current loop outputs, max load 1000Ω, support long-term calibration pH: 5-point multi-slope calibration, calibration points can be set freely; (ORP: 2-point calibration) Differential signal supports solution grounding, which can eliminate some solution leakage interference:With Digital Communications: Two-wire RS485 interface, MODBUS RTU pH/ORP Controller Model:APX1-G2-D Power: DC:+18~36VDC Analog pH Sensor pH Sensor Model: ASP 400-VYD05 Electric Wire: 5m PH: 0~14pH Shaft Material:PPS Working temperature: Medium and low temp environment: 0~80℃, continuously working High temp environment: 80~100℃, continuously working < 60 mins Reference System: Double salt bridge Reference Electrode: Ag/AgCl Electrolyte: kCL solid gel Working pressure: 0~6Bar Glass Head: Transparent low impedance Diameter: 35mm Length: 260 mm( include the cleaning cover) Thread Size:1 inch NTP (both ends) Wash Accessories:Cleaning connector(Optional) Application Pure water/Drinking water/Surface water/Industrial wastewater/Sewage Without temperature compensation pH Sensor Model: ASP 400-TYD05 Electric Wire: 5m PT1000/PT100temperature compensation pH Sensor Model: ASP 400-NYD05 Electric Wire: 5m NTC 10K/ NTC22K/NTC2.25K temperature compensation Analog Online EC controller and sensors (Can show conductivity/ TDS/Sanility/Resistivity/ temperature) Conductivity controller Model: AEC1-T1-A Power: AC: 100~240V 50/60Hz 2 electrodes Measuring electrode technology principle: 2 electrodes Measuring range: Conductivity (full range automatic switching): 0.00~20.000μS/cm Resistivity MΩ.cm:0.00 ~18.00 MΩ.cm TDS (mass-volume concentration mg/L): 0.00 ~10g/L Salinity (mass concentration ‰): 15ppt Temperature (Celsius): -10~150℃ Resolution: Conductivity: 0.001μS/cm  Resistivity: 0.01MΩ.cm TDS (mass-volume concentration mg/L): 0.01mg/L Salinity (mass concentration ‰): 0.01% Temperature (Celsius): 0.1℃ Temperature compensation: manual/automatic selection Accuracy: conductivity/temperature ±1.0%FS/0.5℃ Repeatability: Better than ±0.3%F.S of the measuring range Display screen: 3.2 inches black and white graphic LCD display; 128*64 dot matrix LCD Instrument operation: PET button panel with 4 buttons Calibration method: conductivity standard solution, multi-point calibration Display speed: adjustable, 5 levels of speed regulation Power-off protection: the instrument is powered off, and the set data is permanently retained Menu password: can be used for the management of instrument operation authority, six-digit password setting Relay output: 2 configurable SPST relays, maximum load 3A/250VAC Setting objects: including high/low alarm, water temperature or wash control Dustproof and waterproof grade: IP66 Operating environment: 0~60℃ Storage environment: -20~70℃ Instrument shape: 100*100*120mm Installation opening: 92*92mm Installation method: cabinet panel installation Shell Material: Reinforced ABS Electrical interface: 3 M12*1.5 Glen heads are reserved at the back end of the instrument; the wire diameter is 3~6.5mm Maximum power: 3W Temperature unit: NTC10K (support customization) System language: support customization English Current output: 2-way 0/4~20mA active current loop can be set, load 1000 ohm, support long-term calibration Digital communication interface: without Conductivity controller Model: AEC1-T1-D Power: DC:+18~36VDC 2 electrodes Conductivity controller Model: AEC1-T2-A Power: AC: 100~240V 50/60Hz 2 electrodes Temperature unit: NTC10K (support customization) System language: support customization English Current output: 2-way 0/4~20mA active current loop can be set, load 1000 ohm, support long-term calibration Digital communication interface: 1-way two-wire RS485 interface, MODBUS RTU Conductivity controller Model: AEC1-T2-D Power: DC:+18~36VDC 2 electrodes Analog Conductivity  Sensor Model: ASCK-K1 work pressure:10Bar Operating temperature:0~100℃ Sample Flow Rate/Flow: Not depend on electrode material:316 stainless steel or titanium temperature unit:PT100, PT1000, NTC10K, etc., support customization Body size: A variety of size options, support customization installation size:1/2”NPT Wire lead: separate or integral K Constant: K=1 Measuring Range: 5~2000μS/cm Analog Conductivity  Sensor Model: ASCK-K0.1 K Constant: K=0.1 Measuring Range: 0.5~200μS/cm Analog Conductivity  Sensor Model: ASCK-K0.01 K constant: 0.01 Measuring range:0.05~20μS/cm

"pH Sensor Model: ASP 400-VYD05 Electric Wire: 5m" "PH: 0~14pH Shaft Material:PPS Working temperature: Medium and low temp environment: 0~80℃, continuously working High temp environment: 80~100℃, continuously working < 60 mins Reference System: Double salt bridge Reference Electrode: Ag/AgCl Electrolyte: kCL solid gel Working pressure: 0~6Bar Glass Head: Transparent low impedance Diameter: 35mm Length: 260 mm( include the cleaning cover) Thread Size:1 inch NTP (both ends) Wash Accessories:Cleaning connector(Optional) Application Pure water/Drinking water/Surface water/Industrial wastewater/Sewage" Without temperature compensation "pH Sensor Model: ASP 400-TYD05 Electric Wire: 5m" PT1000/PT100temperature compensation "pH Sensor Model: ASP 400-NYD05 Electric Wire: 5m" NTC 10K/ NTC22K/NTC2.25K temperature compensation


"Conductivity controller Model: AEC1-T1-A Power: AC: 100~240V 50/60Hz 2 electrodes" "Measuring electrode technology principle: 2 electrodes Measuring range: Conductivity (full range automatic switching): 0.00~20.000μS/cm Resistivity MΩ.cm:0.00 ~18.00 MΩ.cm TDS (mass-volume concentration mg/L): 0.00 ~10g/L Salinity (mass concentration ‰): 15ppt Temperature (Celsius): -10~150℃ Resolution: Conductivity: 0.001μS/cm  Resistivity: 0.01MΩ.cm TDS (mass-volume concentration mg/L): 0.01mg/L Salinity (mass concentration ‰): 0.01% Temperature (Celsius): 0.1℃ Temperature compensation: manual/automatic selection Accuracy: conductivity/temperature ±1.0%FS/0.5℃ Repeatability: Better than ±0.3%F.S of the measuring range Display screen: 3.2 inches black and white graphic LCD display; 128*64 dot matrix LCD Instrument operation: PET button panel with 4 buttons Calibration method: conductivity standard solution, multi-point calibration Display speed: adjustable, 5 levels of speed regulation Power-off protection: the instrument is powered off, and the set data is permanently retained Menu password: can be used for the management of instrument operation authority, six-digit password setting Relay output: 2 configurable SPST relays, maximum load 3A/250VAC Setting objects: including high/low alarm, water temperature or wash control Dustproof and waterproof grade: IP66 Operating environment: 0~60℃ Storage environment: -20~70℃ Instrument shape: 100*100*120mm Installation opening: 92*92mm Installation method: cabinet panel installation Shell Material: Reinforced ABS Electrical interface: 3 M12*1.5 Glen heads are reserved at the back end of the instrument; the wire diameter is 3~6.5mm Maximum power: 3W" "Temperature unit: NTC10K (support customization) System language: support customization English Current output: 2-way 0/4~20mA active current loop can be set, load 1000 ohm, support long-term calibration Digital communication interface: without" "Conductivity controller Model: AEC1-T1-D Power: DC:+18~36VDC 2 electrodes" "Conductivity controller Model: AEC1-T2-A Power: AC: 100~240V 50/60Hz 2 electrodes" "Temperature unit: NTC10K (support customization) System language: support customization English Current output: 2-way 0/4~20mA active current loop can be set, load 1000 ohm, support long-term calibration Digital communication interface: 1-way two-wire RS485 interface, MODBUS RTU" "Conductivity controller Model: AEC1-T2-D Power: DC:+18~36VDC 2 electrodes" Analog Conductivity  Sensor Model: ASCK-K1 "work pressure:10Bar Operating temperature:0~100℃ Sample Flow Rate/Flow: Not depend on electrode material:316 stainless steel or titanium temperature unit:PT100, PT1000, NTC10K, etc., support customization Body size: A variety of size options, support customization installation size:1/2”NPT Wire lead: separate or integral" "K Constant: K=1 Measuring Range: 5~2000μS/cm" Analog Conductivity  Sensor Model: ASCK-K0.1 "K Constant: K=0.1 Measuring Range: 0.5~200μS/cm" Analog Conductivity  Sensor Model: ASCK-K0.01 "K constant: 0.01 Measuring range:0.05~20μS/cm"

Digital Online COD Controlller and sensor (RS485 Modbus protocol) "Digital COD Controller Model:DUC2-COD-HA Power:AC100-240V" "COD Display range :0~1000mg/L Resolution turbidity:0.01mg/L Relay output: Two settable SPST relays Analog output: Two settable 0/4~20mA Communication: Two-wire RS485 modbus RTU support JSON text data format Display screen:3.2 inch LCD screen Configuration Information:Power off protection, parameters are retained indefinitely Mounting Method: Wall mounting, pipe clamping, panel installation" "Clock and historical data recording function Maintenance records:Last 100 times Protection grade: IP66 Shell material:Enhanced ABS Instrument size 144*144*120 mm" "Digital COD Controller Model:DUC2-COD-HD Power:DC18-36V" "Digital COD Sensor UV Absorption Method Model:COD UV351L-S" "Measuring Principle :UV254 ultraviolet absorption method Optical distance:6mm Measuring Range(COD): 0.75~500mg/L Resolution(COD) : 0.01mg/L Accuracy(COD): ±3% of the measurement or ±0.5mg/L Measuring Range(TOC): 0.3~200mg/L Accuracy(TOC): ±3% F.S. equiv.KHP Resolution(TOC): 0.1 mg/L Measuring Range(TU compensate) :0~300 NTU Accuracy(TU): ±5% Take the larger one Resolution(TU) :0.1NTU Operating Temperature: 0 ~ 45℃(without freezing) Electric Wire: 5m (Standard)" "Protection Class: IP68 Maximum Pressure: 1 bar User Calibration: 1-point or 2-point calibration Power Information: DC 12V-24V, current <50mA (without cleaning brush) Sensor Diameter: 50mm Sensor Length: 216mm Shell Material POM and 316L (custom titanium alloy available) Mounting: Rear 1"" NPT pipe thread Lead interface: M16 Sensor power supply: 12~24VDC Sensor power consumption: normal measurement: 0.1W; automatic cleaning of mechanical scraper: 3W; abnormal jamming of mechanical scraper: 4.5W; Weight: 720 grams (without wires) Please be note: 1.) The COD value can be measured directly. 2.) BOD/TOC value calculated base on measured COD data through the conversion factor. (Conversion factor model need be build by end user and need used together with our controller.) 3. )COD sensor with turbidity compensation: The measured turbidity value which is mainly used to compensate for COD measurement, and the turbidity value not recommended to be used as measurement data directly" "Digital COD Sensor UV Absorption Method Model:COD UV351H-S" "Measuring Principle :UV254 ultraviolet absorption method Optical distance:2.5 mm Measuring Range(COD): 1~1500mg/L Resolution(COD) : 0.01mg/L Accuracy(COD): ±3% of the measurement or ±0.5mg/L Measuring Range(TOC): 0.4 ~600mg/L Accuracy(TOC): ±3% F.S. equiv.KHP Resolution(TOC): 0.1 mg/L Measuring Range(TU compensate) :0~1000 NTU Accuracy(TU): ±5% F.S. Take the larger one Resolution(TU) :0.1NTU Operating Temperature: 0 ~ 45℃(without freezing) Electric Wire: 5m (Standard)" "Digital Online Multi-parameter Controller (RS485 Modbus protocol) 1-2 pcs different sensors OR 2pcs same(fixed sensors unchangeable,If two same sensor need connected to MCC100, Must be confirm which sensors need connected to the controller before order.) can be connected at the same time, and the detection value of the connected sensor and the corresponding parameter value calculated according to the detection value can be displayed" Digital Multi-parameter Controller Model:MCC100-A2 Power:AC100-240V "Measure Information: Related to sensors (1-2 channels input) Display Screen: 128*64 pixel, 3.2-inch black and white graphic LCD display, backlight and contrast can be adjusted Instrument Operation: PET key panel, 8 keys System Language: English and Chinese Power-off Protection: All setting parameters of the instrument are power-off protection, and the data is retained indefinitely. Time Display Year/Month/day, hour/minute/second History Logs: Record 7800 history data, support data download The recording interval can be set between 1~999 minutes Menu Passw: ord Operation authority management, six-digit password settings" "Relay Output: Two settable SPST relays, Max. load of 3A/250VAC Current Output: Two settable 0/4~20mA current, Max. load 1000Ω Digital Communication Communication interface: 2-wire RS485 interface Communication protocol: Modbus RTU JSON Protection Grade: IP66 Working Temperature: 0~60℃, RH <95% (no condensation) Storage Temperature: -20~70℃, RH<55% (no condensation) Instrument Dimension: 144*144*120mm(hole size: 138*138mm) Installation Method: Panel, wall-mounted, pipe clamping Housing Material :Enhanced ABS Electrical Interface: 3 M12*1.5 glan heads reserved with a wire diameter 3~6.5mm Power Supply: AC: 100~240V 50/60Hz DC: 18~36V Consumption: 24W Packing InformationWeight: 1600g Dimension: 260*230*180mm" Digital Multi-parameter Controller Model:MCC100-A2 Power:DC18-36V "Digital Online Multi-parameter Controller (RS485 Modbus protocol) 1-4 / 1-8 digital sensors with different factors can be connected at the same time, and the detection value of the connected sensor and the corresponding parameter value calculated according to the detection value can be displayed" "Digital Multi-parameter Controller Model:MCC200-A4-A Power : 100~240V50/60Hz 1-4 digital sensors can be connected" "Measure Information: Related to sensors Display Screen:3.2-inch black & white graphic LCD display backlight and contrast: can be adjusted. Instrument Operation: PET key panel, 8 keys System Language: English and Chinese Power-off Protection: All setting parameters of the instrument are power- off protection, and the data is retained indeffnitely. Time Display: Year/Month/day, hour/minute/second History Logs: Record 7800 history data, support data download(Optional) The recording interval: can be set between 1 ~999 minutes Menu Password: six-digit password settings. Relay Output: Wash control, max. Load 3A/250V AC Output extension type (Optional): Relays, current, communication Digital Communication: Comm. interface: 2-wire RS485 interface,Modbus RTU" "Protection Grade: IP66 Working Temperature: 0~60℃ , RH <95% (no condensation) Storage Temperature: -20~70℃ , RH<55% (no condensation) Instrument Dimension: 144*144*1 20mm Installation Method: Panel, wall-mounted, pipe clamping Housing Material: Enhanced ABS Electrical Interface: 3 M1 2*1 .5 glan heads reserved with a wire diameter 3~6.5mm Power Supply AC: 1 00~240V 50/60Hz OR DC:1 8~36V Consumption: 24W Packing Information Weight: 1 600g Dimension: 260*230*1 80mm" "Digital Multi-parameter Controller Model:MCC200-A4-D Power: DC:1 8~36V 1-4 digital sensors can be connected" Transmission expansion module(Optional) Model:EXOUT-M05 5 relays; 5 currents (for digital sensors only) MCC200-A4 need one piece Downloader(Optional) Model:EXOUT-USB "Historical data download RS485~USB The multi-parameter controller can download history records via USB, excluding calibration records. General format of download (time + main measurement + temperature)" "Analog Multi-parameter Controller Can only connect to analog type pH,ORP, EC sensors and the detection value of the connected sensor and the corresponding parameter value calculated according to the detection value can be displayed" "Analog Multi-parameter Controller Model:MCC2000-A Power : 100~240V50/60Hz 1-3 Analog sensors can be connected" "Measure Information: Related to sensors Display Screen:3.2-inch LCD display backlight and contrast: can be adjusted. Instrument Operation: PET key panel, 8 keys System Language: English and Chinese Power-off Protection: All setting parameters of the instrument are power- off protection, and the data is retained indeffnitely. Time Display: Year/Month/day, hour/minute/second History Logs: Record 7800 history data, support data download(Optional) The recording interval: can be set between 1 ~999 minutes Menu Password: six-digit password settings. Relay Output: Wash control, max. Load 3A/250V AC Output extension type (Optional): Relays, current, communication Digital Communication: Comm. interface: 2-wire RS485 interface,Modbus RTU" "Protection Grade: IP66 Working Temperature: 0~60℃ , RH <95% (no condensation) Storage Temperature: -20~70℃ , RH<55% (no condensation) Instrument Dimension: 144*144*1 20mm Installation Method: Panel, wall-mounted, pipe clamping Housing Material: Enhanced ABS Electrical Interface: 3 M1 2*1 .5 glan heads reserved with a wire diameter 3~6.5mm Power Supply AC: 1 00~240V 50/60Hz OR DC:1 8~36V Consumption: 24W Packing Information Weight: 1 600g Dimension: 260*230*1 80mm" "Analog Multi-parameter Controller Model:MCC2000-D Power: DC:1 8~36V 1-3 Analog sensors can be connected" Transmission expansion module(Optional) Model:EXOUT-M05 5 relays; 5 currents (for digital sensors only) MCC200-A4 need one piece Analog type free Chlorine controller Free Chlorine controller Model: ADS2-CL3A AC100-240V "Display Range: 0-200mg/L Resolution: 0.01 mg/L Relay Control: 2 settable SPST relays with a maximum load of 3A/250VAC Analog Current Output :One settable 0/4~20mA current outputs with a maximum load of 1000Ω Communication Method: Two-wire RS485 interface, MODBUS RTU support JSON text data format Display Screen: 128*64 Configuration Information:Power off protection, parameters are retained indefinitely Dimension: 144*144*120 mm Mounting Method: Wall mounting, pipe clamping, panel installation" "Time/Data Record: Record 10000 historical data Maintenance Records : Last 100 times Protection Level : IP66 Shell Material :Enhanced ABS" Free Chlorine controller Model: ADS2-CL3D DC18-36V Digital type free Chlorine controller (RS485 interface) Free Chlorine controller Model: DDS2-CL3A AC100-240V "Display Range: 0-100g/L Resolution: 0.01 mg/L Relay Control: 2 settable SPST relays with a maximum load of 3A/250VAC Analog Current Output :2 settable 0/4~20mA current outputs with a maximum load of 1000Ω Communication Method: Two-wire RS485 interface, MODBUS RTU support JSON text data format Display Screen: 128*64 Configuration Information:Power off protection, parameters are retained indefinitely Dimension: 144*144*120 mm Mounting Method: Wall mounting, pipe clamping, panel installation" "Time/Data Record: record 10000 historical data Maintenance Records : Last 100 times Protection Level : IP66 Shell Material :Enhanced ABS" Free Chlorine controller Model: DDS2-CL3D DC18-36V CS4 Free Chlorine sensor(For drinking water, general sewage and wastewater) "Item.No: CS4MA2 Measuring range: 0.01 … 2.00" "Chlorine sensor with membrane-covered, amperometric 3-electrode system. For the measurement of free inorganic chlorine with reduced pH-dependence, also in sea water. Areas of application: Fresh water and sea water at 10µS/cm~50mS/cm, surfactants are partially tolerated Scope of supply: CS4: sensor, membrane cap, electrolyte Product description: 1.Measurand(s): NaClO (sodium hypochlorite), Ca(OCl)2 (calcium hypochlo- rite), Cl2 (chlorine gas), electrolytically generated chlorine 2.Calibration: at the controller, via analytical chlorine determination by DPD-1 method 3.Interferences: 75 % of ClO2-concentration, 80 % of O3–concentration, combined chlorine may increase the measuring value 4.pH range: 4~9 5.Pressure range: 0~3.0 bar, no pressure surges and/or fluctuations 6.Temperature range: 0~45 ℃ 7.Standard without Integrated automatic temperature compensation (Optional function) 8.Response time: T90 about 2 min. 9.Flow rate: about 30 l/h, low flow- dependence 10.Shaft length: standard 175 mm, and up to 220 mm in length (mA- Version) 11.Connection: for mA-version 2-pole terminal, M12 male or Modbus RTU with M12 male" "Output signal: 4 … 20 mA Power supply: 12…30 V DC R L : 50Ω … 900Ω Connection: for mA-version 2-pole terminal, M12 male or Modbus RTU with M12 male Applicable to: drinking water, general sewage and wastewater" "Item.No: CS4MA5 Measuring range: 0.01 … 5.00" "Item.No: CS4MA10 Measuring range: 0.01 … 10.00" "Item.No: CS4MA20 Measuring range: 0.01 … 20.00" "Item.No: CS4MA200 Measuring range: 0.5 … 200.0" "Item.No: CS4MA2-M12 Measuring range: 0.01 … 2.00" "Item.No: CS4MA5-M12 Measuring range: 0.01 … 5.00" "Item.No: CS4MA10-M12 Measuring range: 0.01 … 10.00" "Item.No: CS4MA20-M12 Measuring range: 0.01 … 20.00" "Item.No: CS4MA200-M12 Measuring range: 0.5 … 200.0" "Item.No: CS4H-M0c Measuring range: 0.005 … 2.000" "Output signal: RS485 Modbus RTU Power supply: 9~30 V DC about 20~56 mA Connection: for mA-version 2-pole terminal, M12 male or Modbus RTU with M12 male Applicable to: drinking water, general sewage and wastewater" "Item.No: CS4N-M0c Measuring range: 0.05 … 20.00" "Item.No: CS4L-M0c Measuring range: 0.5 … 200.0" Flow cell-Type 01 Total Chlorine Sensor(RS485 Modbus protocol, Pool water) "Total chlorine sensor Item NO.:CP4.0MA0,5 Measuring range:0,05 … 0,50ppm" "Chlorine sensor with membrane-covered, amperometric 3-electrode system. To the Recording of the total chlorine with greatly reduced dependence on the pH value. Product description: 1. Measured variable(s): NaClO (sodium hypochlorite), Ca(ClO)2 (calcium hypochlorite), Cl2 (chlorine gas), electrolytically generated chlorine 2.Calibration: on the controller, using analytical chlorine determination, DPD-4 method (DPD-1 + DPD-3) 3.Disturbances: – ClO2 is recorded 100%, – O3 is measured with a slope of approx. 130% (Factor 1.3 based on the chlorine slope) 4.Resolution: depending on type 0.1 … 0.001 ppm 5. pH range: 4 … 12 6. Pressure range: – Operation without a circlip: 0 ... 0.5 bar, no pressure surges and/or vibrations – Operation with retaining ring: 0 ... 3.0 bar, no pressure surges and/or vibrations 7.Temperature range: 0 … 45 °C (no ice crystals in the water) 8. Sensor with automatic temperature compensation 9.Response time: T90 approx. 3 min. 10. Absence of disinfectant: max. 24 h 11. Flow rate: approx. 15 … 30 l/h (low flow dependency is available) 12. Shaft length: standard 175 mm, up to 220 mm (in mA version) 13. Connector: Standard 4-pin connector; mA version 2-pin clamp, M12 socket or Modbus RTU with M12 socket 14. Materials: microporous hydrophilic membrane, PVC-U, Peek, stainless steel 1.4571 Areas of application: 15.Swimming pool, drinking water, surfactants are partially tolerated. Scope of delivery: 16. CP4 sensor, membrane cap, electrolyte, operating instructions" "Resolution: 0,01 ppm Output signal:4 … 20 mA Power supply: 12 … 30 V DC  RL : 50Ω … 900Ω Areas of application: Swimming pool, drinking water, surfactants are partially tolerated. Scope of delivery: CP4 sensor, membrane cap, electrolyte, operating instructions" "Total chlorine sensor Item NO.:CP4.0MA2 Measuring range:0,01 … 2,00ppm" "Total chlorine sensor Item NO.:CP4.0MA5 Measuring range:0,01 … 5,00ppm" "Total chlorine sensor Item NO.:CP4.0MA10 Measuring range:0,01 … 10,00ppm" "Total chlorine sensor Item NO.:CP4.0MA20 Measuring range:0,01 … 20,00ppm" "Total chlorine sensor Item NO.:CP4.0MA0,5-M12 Measuring range:0,05 … 0,50ppm" "Total chlorine sensor Item NO.:CP4.0MA2-M12 Measuring range:0,01 … 2,00ppm" "Total chlorine sensor Item NO.:CP4.0MA5-M12 Measuring range:0,01 … 5,00ppm" "Total chlorine sensor Item NO.:CP4.0MA10-M12 Measuring range:0,01 … 10,00ppm" "Total chlorine sensor Item NO.:CP4.0MA20-M12 Measuring range:0,01 … 20,00ppm" "Total chlorine sensor Item NO.: CP4.0H-M0c Measuring range:0,005 … 2,00 ppm" "Resolution: 0,01 ppm Output signal:Modbus RTU Power supply: 9 … 30 VDC approx. 20…56mA Areas of application: Swimming pool, drinking water, surfactants are partially tolerated. Scope of delivery: CP4 sensor, membrane cap, electrolyte, operating instructions" "Total chlorine sensor Item NO.: CP4.0N-M0c Measuring range:0,05 … 20,00ppm" Flow cell-Type 01 Flow cell

















.

.

.


Tidak ada komentar:

Posting Komentar