Jumat, 11 Februari 2022

081362449440 Jual Digital Thermometers (PET, DCT) > Walker Tulsa Ranger™ > RANGER- CABLED VERSION 25' _ Digital Thermometers (PET, DCT) > Walker Tulsa Ranger™ > 25' Light OS - Ranger Digital Thermometers (PET,DCT) RANGER WITH ROTATING PROBE ASSEMBLY LIGHT OS RANGER WITH ROTATING PROBE ASSEMBLY 25' Light OS - Ranger RANGER- CABLED VERSION 25', Distributor Jakarta Indonesia Brochure PDF Harga Rp...

BINTANG INSTRUMENT 

HP : 081362449440 / 081310157965

Email : b081362449440@yahoo.com

Up : Mr Jonathan

============================

 

 

 

Digital Thermometers (PET, DCT) SERIES :

1. 

Digital Thermometers (PET, DCT)

Series : RANGER- CABLED VERSION 25'


Walker Tulsa Ranger™ CSA EX ia IIc

This unit has been designed in accordance with Chapter 7 Section 2 Third Edition, May 2018.

FEATURES

- User selectable auto-off timer to save battery life

- Resolution of 0.1 and 0.01

Temperature range -40 to 400 degrees F

- 10-minute timer on backlight to save battery life

- Averaging function

- Auto-Sample function with average feature

- Easy F to C switching

- Backlit LCD with indicating arrows indicating rate of change

- 4 Point calibration

- Cable units 25' standard length, additional lengths are available

- Highly durable membrane switch faceplate

- Glow in the dark keypad

- Auto backlight upon power up function (Hold)

- Data Logging through Hidden Data Port via custom USB cable (Upon request).

SPECIFICATIONS

Display: Amber backlit LCD with 0.45" characters with trend indication arrows and low battery and fault indication

Temperature list with averaging function

Selectable Resolution of 0.1 or 0.01

User Selectable auto-off timer

CONSTRUCTION:

Stainless steel temperature probe and sensor.

Electronics and display in CNC machined anodized Aluminum or stainless steel enclosure.

Highly durable display window, graphics and membrane switches.

Weight: .7lbs

Temperature: Resolution to 0.01 Degrees

Average Calibrated Accuracy: ±0.080F (32-300 F) & ±0.048C (0-150C)

Time Constant: 7 seconds in circulated water bath Constant: (63.2% response to temperature change)

Electronics: Ultra Low Power Microcontroller, FLASH Memory, 20 bit A/D Converter

Recommended Ambient Temperature Range for best accuracy 32 to 112 F, 0 to 44 C

Sensor: 1000 Ohm, Class A Platinum RTD

Immersion depth 4", 11cm

Battery: Energizer Ultimate Lithium L92 Intrinsically Safe Rated AAA, Battery life (depending upon use) 25-150 hrs Battery Operating Range: -40°C to 60°C (-40°F to 140°F)

TYPICAL APPLICATIONS

Custody transfer, temperature baths, reference, temperature calibration for flow meters, thermowells, provers, reference, distillations, melting point tests, and flash point tests. Industries: Laboratory, Petroleum, Pipeline, Pharmaceutical, Food & many more.

Certifications: Intrinsically safe for use in Class I, Division I Groups A, B, C, & D. Class 1, Zone 0, Group IIC Hazardous Locations

 

 ======================================================================

 


2.

Digital Thermometers (PET, DCT)

Series : 25' Light OS - Ranger

 

Walker Tulsa Ranger™ CSA EX ia IIc

This unit has been designed in accordance with Chapter 7 Section 2 Third Edition, May 2018.

FEATURES

- User selectable auto-off timer to save battery life

- Resolution of 0.1°

Temperature range -40° to 400° F

- 10-minute timer on backlight to save battery life

- Easy F to C switching

- Backlit LCD with indicating arrows indicating rate of change

- 4 Point calibration

- Cable units 25' standard length, additional lengths are available

- 1/4" Probe with tappered brass weight

- Highly durable membrane switch faceplate

- Glow in the dark keypad

- Auto backlight upon power up function (Hold)

SPECIFICATIONS

Display: Amber backlit LCD with 0.45" characters with trend indication arrows and low battery and fault indication

Selectable Resolution of 0.1°

User Selectable auto-off timer

CONSTRUCTION:

Stainless steel temperature probe and sensor.

Electronics and display in CNC machined anodized Aluminum or stainless steel enclosure.

Highly durable display window, graphics and membrane switches.

Weight: .7lbs

Temperature: Resolution to 0.1°

Average Calibrated Accuracy: ±0.080F (32-300 F) & ±0.048C (0-150C)

Time Constant: 7 seconds in circulated water bath Constant: (63.2% response to temperature change)

Electronics: Ultra Low Power Microcontroller, FLASH Memory, 20 bit A/D Converter

Recommended Ambient Temperature Range for best accuracy 32 to 112 F, 0 to 44 C

Sensor: 1000 Ohm, Class A Platinum RTD

Immersion depth 4", 11cm

Battery: Energizer Ultimate Lithium L92 Intrinsically Safe Rated AAA, Battery life (depending upon use) 25-150 hrs Battery Operating Range: -40°C to 60°C (-40°F to 140°F)

TYPICAL APPLICATIONS

Custody transfer, temperature baths, reference, temperature calibration for flow meters, thermowells, provers, reference, distillations, melting point tests, and flash point tests. Industries: Laboratory, Petroleum, Pipeline, Pharmaceutical, Food & many more.

Certifications: Intrinsically safe for use in Class I, Division I Groups A, B, C, & D. Class 1, Zone 0, Group IIC Hazardous Locations


=================================================

3.Digital Thermometers (PET, DCT)

Series : RANGER WITH ROTATING PROBE ASSEMBLY

 


 

Description

Walker Tulsa Ranger™ CSA EX ia IIc

This unit has been designed in accordance with Chapter 7 Section 2 Third Edition, May 2018.

FEATURES

- User selectable auto-off timer to save battery life

- Resolution of 0.1 and 0.01

- Temperature range -40 to 400 degrees F

- 10-minute timer on backlight to save battery life

- Averaging function

- Auto-Sample function with average feature

- Easy F to C switching

- Backlit LCD with indicating arrows indicating rate of change

- 4 Point calibration

- Rotating rigid probe (10" Stock Length)

- Cable units available

- Highly durable membrane switch faceplate

- Glow in the dark keypad

- Auto backlight upon power up function (Hold)

- Data Logging through Hidden Data Port via custom USB cable (Upon request).

- Custom Anodized Aluminum Case available for Rigid Rangers Models see 6978087.

SPECIFICATIONS

Display: Amber backlit LCD with 0.45" characters with trend indication arrows and low battery and fault indication

Temperature list with averaging function

Selectable Resolution of 0.1 or 0.01

User Selectable auto-off timer

CONSTRUCTION:

Stainless steel temperature probe and sensor.

Electronics and display in CNC machined anodized Aluminum or stainless steel enclosure.

Highly durable display window, graphics and membrane switches.

Weight: .7lbs

Temperature: Resolution to 0.01 Degrees

Average Calibrated Accuracy: ±0.080F (32-300 F) & ±0.048C (0-150C)

Time Constant: 7 seconds in circulated water bath Constant: (63.2% response to temperature change)

Electronics: Ultra Low Power Microcontroller, FLASH Memory, 20 bit A/D Converter

Recommended Ambient Temperature Range for best accuracy 32 to 112 F, 0 to 44 C

Sensor: 1000 Ohm, Class A Platinum RTD

Immersion depth 4", 11cm

Battery: Energizer Ultimate Lithium L92 Intrinsically Safe Rated AAA, Battery life (depending upon use) 25-150 hrs Battery Operating Range: -40°C to 60°C (-40°F to 140°F)

TYPICAL APPLICATIONS

Custody transfer, temperature baths, reference, temperature calibration for flow meters, thermowells, provers, reference, distillations, melting point tests, and flash point tests. Industries: Laboratory, Petroleum, Pipeline, Pharmaceutical, Food & many more.

Certifications: Intrinsically safe for use in Class I, Division I Groups A, B, C, & D. Class 1, Zone 0, Group IIC Hazardous Locations

 

 

 ============================================


4. Digital Thermometers (PET, DCT)

Series : RANGER WITH ROTATING PROBE ASSEMBLY LIGHT OS

 


 

Description

Walker Tulsa Ranger™ CSA EX ia IIc

This unit has been designed in accordance with Chapter 7 Section 2 Third Edition, May 2018.

FEATURES

- User selectable auto-off timer to save battery life

- Resolution of 0.1 

- Temperature range -40 to 400 degrees F

- 10-minute timer on backlight to save battery life

- Easy F to C switching

- Backlit LCD with indicating arrows indicating rate of change

- 4 Point calibration

- Rotating rigid probe (10" Stock Length)

- Cable units available

- Highly durable membrane switch faceplate

- Glow in the dark keypad

- Auto backlight upon power up function (Hold)

- Custom Anodized Aluminum Case available for Rigid Rangers Models see 6978087.

SPECIFICATIONS

Display: Amber backlit LCD with 0.45" characters with trend indication arrows and low battery and fault indication

User Selectable auto-off timer

CONSTRUCTION:

Stainless steel temperature probe and sensor.

Electronics and display in CNC machined anodized Aluminum or stainless steel enclosure.

Highly durable display window, graphics and membrane switches.

Weight: .7lbs

Temperature: Resolution to 0.1 Degrees

Average Calibrated Accuracy: ±0.080F (32-300 F) & ±0.048C (0-150C)

Time Constant: 7 seconds in circulated water bath Constant: (63.2% response to temperature change)

Electronics: Ultra Low Power Microcontroller, FLASH Memory, 20 bit A/D Converter

Recommended Ambient Temperature Range for best accuracy 32 to 112 F, 0 to 44 C

Sensor: 1000 Ohm, Class A Platinum RTD

Immersion depth 4", 11cm

Battery: Energizer Ultimate Lithium L92 Intrinsically Safe Rated AAA, Battery life (depending upon use) 25-150 hrs Battery Operating Range: -40°C to 60°C (-40°F to 140°F)

TYPICAL APPLICATIONS

Custody transfer, temperature baths, reference, temperature calibration for flow meters, thermowells, provers, reference, distillations, melting point tests, and flash point tests. Industries: Laboratory, Petroleum, Pipeline, Pharmaceutical, Food & many more.

Certifications: Intrinsically safe for use in Class I, Division I Groups A, B, C, & D. Class 1, Zone 0, Group IIC Hazardous Locations

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

.

.

.

..

.

 